- Tunnels
- Tunnel code (B1000C): in tanks, —; in other carriage, Net explosive mass over 1,000 kg per transport unit: prohibited in B, C, D, E. At or under 1,000 kg: prohibited in C, D, E. Class 1 quantity-qualified: A only above 1,000 kg NEM; A and B at or under it. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 50 per transport unit under 1.1.3.6, counted ×20 toward the 1,000-point limit (1.1.3.6.3 note a) (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 1.5 (Explosive substances or articles, Division 1.5) (ADR 5.2.2.2.2, label model No. 1.5; paraphrase, not yet reviewed)
- Packing
- Packing instruction P116: Explosives in bags, receptacles or sheets, inside outer bags, boxes, drums or jerricans; no intermediate packaging. Packing instruction IBC100: IBC100 covers the explosives UN 0082, 0222, 0241, 0331 and 0332 in metal, flexible, rigid plastics or composite IBCs, free-flowing only. Special packing provision PP61: UN 0082, 0241, 0331 and 0332: no inner packagings needed in leakproof removable-head drums. Special packing provision PP62: UN 0082, 0241, 0331 and 0332: no inner packagings needed if the explosive is held in liquid-impervious material. Special packing provision PP64: UN 0331: no inner packagings needed when 5H2, 5H3 or 5H4 bags are the outer packaging. Mixed packing provision MP20: Class 1: mix only with substances of the same UN number, or under MP24; never with other classes or non-ADR goods. (ADR 4.1.4.1, P116, 4.1.4.2, IBC100, 4.1.4.1, P116, PP61, 4.1.4.1, P116, PP62, 4.1.4.1, P116, PP64, 4.1.10.4, MP20; paraphrase, not yet reviewed)
- Tanks
- Portable tank instruction T1: Portable tank, Class 1 and 3–9: test 1.5 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.2. Portable tank provision TP17: Thermal insulation of the tank may only use inorganic, non-combustible materials. Portable tank provision TP32: Conditions for UN 0331, 0332 and 3375 in portable tanks: relief device, suitability test for 3375, no caking. Tank code S2.65AN(+): ADR tank code for Classes 1 and 3–9: solid tank, 2.65 bar, openings A, valves/devices N, suffix (+). — S: tank for solid-state substances (powdery or granular); 2.65: minimum calculation pressure of 2.65 bar (see 6.8.2.1.14); A: filling or discharge openings at the bottom, each with 2 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU3: Shell interior and every part touching the substance kept clean; no lubricant that could react dangerously with it on pumps or valves. Tank provision TU12: When the tank changes use, shell and equipment must be thoroughly cleaned of residues before and after carrying this substance. Tank provision TU41: Tank suitability must be shown to the competent authority of every country of transit or destination; the substance must not be left long enough to cake. Tank provision TC8: Shells must be of aluminium or aluminium alloy and may be designed for an external design pressure of at least 5 kPa (0.05 bar). Tank provision TA1: Tanks must not be approved for carrying organic substances. Tank provision TA5: Only tanks with tank code S2.65AN(+) may be used; the 4.3.4.1.2 hierarchy does not apply. Vehicle for tank carriage: EX/III — Vehicle type for carrying Class 1 explosive substances and articles; needs ADR approval to Part 9. (ADR 4.2.5.2.6, portable tank instruction T1, 4.2.5.3, TP17, 4.2.5.3, TP32, 4.3.4.1.1, tank code S2.65AN(+), 4.3.5, TU3, 4.3.5, TU12, 4.3.5, TU41, 6.8.4 (a), TC8, 6.8.4 (c), TA1, 6.8.4 (c), TA5, 9.1.1.2, EX/III vehicle; paraphrase, not yet reviewed)
- Carriage
- Carriage provision V2: Class 1 packages may only travel on EX/II or EX/III vehicles meeting Part 9; the quantity carried decides which type is needed (7.5.5.2). Carriage provision V12: IBCs of type 31HZ2 (31HA2, 31HB2, 31HN2, 31HD2, 31HH2) must be carried in closed vehicles or closed containers. Loading provision CV1: Public-place loading/unloading: special permission needed inside built-up areas, advance notice to the authorities outside them. Loading provision CV2: Clean the loading surface thoroughly before loading; no fire or naked flame on, near, or while loading/unloading the vehicle. Loading provision CV3: Pointer: the Class 1 quantity limits per transport unit in 7.5.5.2 apply. Operation provision S1: Class 1 operating rules: training, official escort, no smoking, loading places, 50 m spacing, supervision thresholds by division, locking. (ADR 7.2.4, V2, 7.2.4, V12, 7.5.11, CV1, 7.5.11, CV2, 7.5.11, CV3, 8.5, S1; paraphrase, not yet reviewed)