- Tunnels
- Tunnel code (D): in tanks, Prohibited in D, E; in other carriage, Prohibited in D, E. Categories A, B, C. (ADR 8.6.4; from the ADR table itself)
- Small-load exemption
- Transport category 1: at most 20 per transport unit under 1.1.3.6, counted ×50 toward the 1,000-point limit (ADR 1.1.3.6.3; from the ADR table itself)
- Labels
- Labels: model 4.1 (Flammable solids, self-reactive and polymerizing substances, and solid desensitized explosives) (ADR 5.2.2.2.2, label model No. 4.1; paraphrase, machine-reviewed (two independent readings of the UNECE text agreed with it), not yet reviewed by a person)
- Packing
- Packing instruction P001: General packing instruction for liquids: combination, single, composite packagings and pressure receptacles, with capacity/mass limits by packing group. Packing instruction IBC03: Liquids under IBC03 may use metal 31-series, rigid plastics 31H1/31H2 or a wider set of 31H composite IBCs. Special packing provision PP93: UN 3532 and 3534 packagings must be built to vent gas or vapour so pressure cannot burst them if stabilization fails. Special packing provision B19: UN 3532 and 3534 IBCs must be built to vent gas or vapour so pressure cannot burst them if stabilization fails. (ADR 4.1.4.1, P001, 4.1.4.2, IBC03, 4.1.4.1, P001, PP93, 4.1.4.2, IBC03, B19; paraphrase, machine-reviewed (two independent readings of the UNECE text agreed with it), not yet reviewed by a person)
- Tanks
- Portable tank instruction T7: Portable tank, Class 1 and 3–9: test 4 bar; shell See 6.7.2.4.2; relief Normal; bottom openings See 6.7.2.6.3. Portable tank provision TP4: Degree of filling capped at 90 %, or another figure the competent authority approves. Portable tank provision TP6: Tank needs pressure-relief devices sized to its capacity and the substance so it cannot burst, even in a fire. Tank code L4BN(+): ADR tank code for Classes 1 and 3–9: liquid tank, 4 bar, openings B, valves/devices N, suffix (+). — L: tank for liquid-state substances (liquids, or solids handed over molten); 4: minimum calculation pressure of 4 bar (see 6.8.2.1.14); B: filling or discharge openings at the bottom, each with 3 closures; N: has no 6.8.2.2.6 breather device and is not hermetically closed; (+): alternative use of the tank for other substances is allowed only where the certificate of type approval says so (3.2.1 column (12); 4.3.4.1.3) Tank provision TU30: Fill as set in the tank type-approval test report, and never above 90 % of capacity. Tank provision TE11: Shell and service equipment must keep out foreign matter, prevent leakage and stop dangerous decomposition pressure; a suitable safety valve suffices. Vehicle for tank carriage: AT — Tank vehicle for dangerous goods that is not EX/III, FL or a MEMU: tanks over 1 m³ / 3 m³, or battery-vehicle over 1 m³. (ADR 4.2.5.2.6, portable tank instruction T7, 4.2.5.3, TP4, 4.2.5.3, TP6, 4.3.4.1.1, tank code L4BN(+), 4.3.5, TU30, 6.8.4 (b), TE11, 9.1.1.2, AT vehicle; paraphrase, machine-reviewed (two independent readings of the UNECE text agreed with it), not yet reviewed by a person)
- Carriage
- Carriage provision V8: Temperature control applies: follow 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. Loading provision CV15: Pointer: 7.5.5.3 applies — organic peroxides, self-reactive substances (types B to F) and polymerizing substances are limited to 20 000 kg per transport unit. Loading provision CV21: Temperature-controlled carriage: inspect unit, brief the carrier, carry enough refrigerant, keep packages accessible, hold control temperature throughout. Loading provision CV22: Load for free air circulation; above 5 000 kg per vehicle or large container, split into stacks ≤ 5 000 kg with ≥ 0.05 m gaps. Operation provision S4: Temperature control: see 7.1.7; not applicable to inhibitor-stabilized 3.1.2.6 substances with SADT above 50 °C. (ADR 7.2.4, V8, 7.5.11, CV15, 7.5.11, CV21, 7.5.11, CV22, 8.5, S4; paraphrase, machine-reviewed (two independent readings of the UNECE text agreed with it), not yet reviewed by a person)